Foundation course · Basic Electrical

Basic Electrical for Solar

The electrical basics every solar designer and installer needs — explained simply, with formulas, worked examples, a practice calculator and a quiz. Free study material; join the live course for hands-on practice.

Join the live course
Lesson 1

The basic electrical quantities

Think of electricity like water in a pipe: voltage is the pressure, current is the flow, and resistance is how narrow the pipe is.

QuantitySymbolUnitWhat it means
Voltage (potential difference)Vvolt (V)The "push" that drives current. Home supply in India: 230 V AC.
CurrentIampere (A)The flow of charge through a conductor.
ResistanceRohm (Ω)Opposition to current. Longer or thinner wires have more resistance.
PowerPwatt (W), kWThe rate of using or producing energy.
EnergyEkWh ("unit")Power × time. 1 unit on your bill = 1 kWh.
Frequencyfhertz (Hz)How many times AC changes direction per second. India: 50 Hz.
Charge / battery capacityQampere-hour (Ah)Battery storage. Energy (Wh) = Ah × battery voltage.

Conductors

Let current flow easily: copper, aluminium, silver. Copper is used for most solar DC and house wiring; aluminium for large LT/HT cables.

Insulators

Block current: PVC, XLPE, rubber, glass, porcelain. Cable insulation and the PV module back-sheet are insulators.

Lesson 2

Ohm's law and electrical power

Ohm's law links voltage, current and resistance. Combine it with the power formula and you can find any value from two others.

  1. Ohm's law

    V = I × R I = V ÷ R R = V ÷ I

    Example: a 12 V battery across a 4 Ω heater → I = 12 ÷ 4 = 3 A.

  2. Power

    P = V × I P = I² × R P = V² ÷ R

    Example: a 230 V, 2 kW geyser draws I = 2000 ÷ 230 ≈ 8.7 A.

  3. Energy

    E (kWh) = P (kW) × hours

    Example: a 1.5 kW AC running 8 h/day uses 12 kWh/day ≈ 360 units/month.

  4. Losses in cables

    Power loss = I² × R

    Doubling the current makes cable losses four times bigger. That is why solar strings use high voltage and low current.

Lesson 3

Series and parallel circuits

The same rules apply to resistors, solar panels and batteries.

Series (end to end)

  • Same current through every part
  • Voltages add up
  • Rtotal = R₁ + R₂ + R₃ …
  • Solar: panels in a string — 6 × 41.6 V Vmp = 250 V
  • Batteries: 4 × 12 V in series = 48 V, same Ah

Parallel (side by side)

  • Same voltage across every branch
  • Currents add up
  • 1/Rtotal = 1/R₁ + 1/R₂ + …
  • Solar: 2 identical strings in parallel = double current, same voltage
  • Batteries: 2 × 150 Ah, 12 V in parallel = 300 Ah at 12 V
Lesson 4

AC, DC, single-phase and three-phase

DC — direct current

Flows in one direction at a steady voltage. Produced by solar panels and batteries. DC arcs do not self-extinguish, so DC switches and fuses must be DC-rated.

AC — alternating current

Reverses direction 50 times a second in India. Supplied by the grid and by the inverter, which converts the panels' DC into AC.

SupplyTypical voltage (India)Power formulaUsed for
DC12 / 24 / 48 V battery; 300–1000 V PV stringP = V × IPanels, batteries, charge controllers
Single-phase AC230 V phase-to-neutralP = V × I × PFHomes, small shops, inverters up to ~6 kW
Three-phase AC400–415 V line-to-lineP = √3 × VL × IL × PFLarge homes, industry, pumps, inverters above ~6 kW

Power factor (PF)

Ratio of real power (kW) to apparent power (kVA): kW = kVA × PF. Heaters and bulbs have PF ≈ 1; motors and ACs are around 0.8. Inverters and generators are rated in kVA.

RMS value

The "230 V" we quote is the RMS (effective) value. The peak of the AC wave is about 1.414 × 230 ≈ 325 V.

Lesson 5

Cables, wire sizes and colour codes

Choose a cable by its current rating first, then check the voltage drop.

Copper cable sizeApprox. current (A)Typical home use
1.5 mm²10–14Lighting and fan circuits
2.5 mm²16–20Socket circuits
4 mm²25–30Air conditioner, geyser, solar DC strings
6 mm²32–40Main supply to the DB, larger solar strings
10 mm²45–55Main incomer, inverter output of larger systems

Ratings are approximate for PVC-insulated copper in conduit. Always apply the manufacturer's derating for temperature, grouping and installation method.

Voltage drop (V) = 2 × L × I × ρ ÷ A (ρ copper ≈ 0.0175 Ω·mm²/m) — keep DC ≤ 2%, AC ≤ 3%

AC colour code

  • Current standard (IS 732:2019 / IEC): L1 brown, L2 black, L3 grey, neutral blue, earth green-yellow
  • Older Indian wiring: phases red / yellow / blue, neutral black, earth green

Solar DC cables

  • Use UV-resistant solar cable (EN 50618 / IEC 62930), usually 4 or 6 mm²
  • Common practice: red = positive, black = negative
  • Use matching MC4 connectors from the same brand
Lesson 6

Protection devices and earthing

DeviceProtects againstKey points
FuseOvercurrent, short circuitMelts and must be replaced. Solar uses gPV DC fuses on strings.
MCBOverload, short circuitResettable. Curve B trips at 3–5 × rated current (lighting), C at 5–10 × (general, inverters), D at 10–20 × (motors).
RCCB / RCDEarth leakage, electric shockTrips when current leaks to earth: 30 mA for human safety, 100–300 mA for fire protection.
MCCBOverload, short circuitLarger currents (typically 100–1600 A), adjustable trip settings.
SPDLightning and voltage surgesType 2 SPDs on both the DC and AC sides of a solar system.
IsolatorSafe disconnection for maintenanceNo automatic tripping. Use a DC-rated isolator before the inverter.

Earthing

Connects metal frames and equipment to the ground so that fault current flows safely and protection devices can trip. Solar systems need earthing for module frames and structures, the inverter body and the SPDs, plus a lightning arrester where required.

Good earth resistance

Measured with an earth tester. A common target is below 5 Ω, and lower for large plants. Keep the earth pit moist and check it every year.

Lesson 7

Measuring instruments

Multimeter

Measures voltage (AC/DC), current and resistance, and checks continuity. Measure voltage in parallel and current in series. Use it to check string Voc before connecting the inverter.

Clamp meter

Measures current without cutting the wire: clamp around one conductor only. A DC clamp meter is needed for solar string current.

Insulation tester (megger)

Applies 500–1000 V to check cable and module insulation. Low readings mean damaged insulation or moisture.

Earth tester and energy meter

The earth tester measures earth-pit resistance. The energy meter records kWh; a net meter records import and export separately.

Lesson 8

Electrical safety rules

  1. Isolate, lock and tag

    Switch off and lock out the supply, and tag it so no one switches it back on while you work.

  2. Test before you touch

    Always confirm "dead" with a tested voltage tester. Solar panels are live whenever there is daylight; you cannot switch them off at the panel.

  3. Wear PPE

    Insulated gloves, safety shoes, a helmet, safety glasses, and a harness when working at height.

  4. Never break DC under load

    Open the DC isolator only after the inverter has stopped; unplugging MC4 connectors under load can cause an arc.

  5. Know first aid

    In case of shock, cut the power first. Never touch the person while they are still in contact with the supply.

Practice

Ohm's law, power and energy calculator

Change any value — results and the full working update instantly.

Supply

V (line-to-line for 3-phase)
A
1 for DC / heaters

Usage

h
₹ per unit

Results

Power
Apparent power
Resistance
Energy per day
Units per month
Monthly cost
Study material

Quick formula sheet

Revise before your exam or site visit. Use "Print / save notes as PDF" at the top to keep a copy.

TopicFormula / fact
Ohm's lawV = I × R
DC powerP = V × I = I²R = V²/R
Single-phase AC powerP = V × I × PF
Three-phase AC powerP = 1.732 × VL × IL × PF
EnergykWh = kW × hours (1 unit = 1 kWh)
kW and kVAkW = kVA × PF
Series resistanceR = R₁ + R₂ + …
Parallel resistance1/R = 1/R₁ + 1/R₂ + …
Battery energyWh = Ah × V
Voltage drop (2-wire)Vd = 2 × L × I × ρ ÷ A, ρCu ≈ 0.0175
AC peak voltageVpeak = 1.414 × VRMS (230 V → 325 V)
India supply230 V single-phase, 400–415 V three-phase, 50 Hz
RCCB for shock protection30 mA

Key terms

  • Short circuit: phase touches neutral or earth, causing a very high current
  • Overload: more current than the circuit is designed for
  • Earth leakage: current escaping to earth through insulation or a person
  • DB (distribution board): the panel holding the MCBs and RCCB
  • Voc / Isc: a panel's open-circuit voltage and short-circuit current
  • Vmp / Imp: voltage and current at maximum power
  • Inverter: converts DC to AC
  • Net meter: a bidirectional meter recording import and export
Track your progress

Basic Electrical topics checklist

Test yourself

Basic Electrical quiz

1. A 24 V supply is connected across a 6 Ω resistor. What is the current?

I = V ÷ R = 24 ÷ 6 = 4 A.

2. A 1 kW heater runs for 5 hours. How many units does it use?

Energy = 1 kW × 5 h = 5 kWh = 5 units.

3. Six 40 V panels are connected in series. What is the string voltage?

In series the voltages add: 6 × 40 = 240 V. The current stays the same.

4. Which device protects a person from electric shock caused by earth leakage?

An RCCB trips when leakage current to earth exceeds its rating — 30 mA for personal safety.

5. What is the supply frequency in India?

India uses 50 Hz AC.

6. Two identical 12 V, 100 Ah batteries are connected in parallel. The result is…

In parallel the voltage stays the same and the capacities add.

7. A 10 kVA inverter supplies a load with a power factor of 0.8. What real power can it deliver?

kW = kVA × PF = 10 × 0.8 = 8 kW.

8. Why are solar panels dangerous even when the inverter is switched off?

Panels generate voltage in daylight, so the DC cables stay live until the strings are isolated.